Comparison of intensity modulated radiotherapy (IMRT) with intensity modulated particle therapy (IMPT) using fixed beams or an ion gantry for the treatment of patients with skull base meningiomas

Katsura Kosaki1,3, Swantje Ecker2, Daniel Habermehl3, Stefan Rieken3, Oliver Jäkel2,3,4, Klaus Herfarth3, Jürgen Debus3 and Stephanie E Combs3*

Author Affiliations

1 Department of Radiology, Nagoya City University Hospital, Nagoya, Japan

2 Heidelberg Ion Therapy Center (HIT), Heidelberg, Germany

3 Department of Radiation Oncology, University Hospital of Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany

4 Department of Medical Physics, German Cancer Research Center (dkfz), Heidelberg, Germany

For all author emails, please log on.

Radiation Oncology 2012, 7:44 doi:10.1186/1748-717X-7-44

Published: 22 March 2012

Abstract

Background

To examine the potential improvement in treatment planning for patients with skull base meningioma using IMRT compared to carbon ion or proton beams with and without a gantry.

Methods

Five patients originally treated with photon IMRT were selected for the study. Ion beams were chosen using a horizontal beam or an ion gantry. Intensity controlled raster scanning and the intensity modulated particle therapy mode were used for plan optimization. The evaluation included analysis of dose-volume histograms of the target volumes and organs at risk.

Results

In comparison with carbon and proton beams only with horizontal beams, carbon ion treatment plans could spare the OARs more and concentrated on the target volumes more than proton and photon IMRT treatment plans. Using only a horizontal fixed beam, satisfactory plans could be achieved for skull base tumors.

Conclusion

The results of the case studies showed that using IMPT has the potential to overcome the lack of a gantry for skull base tumors. Carbon ion plans offered slightly better dose distributions than proton plans, but the differences were not clinically significant with established dose prescription concepts.

Keywords:
Plan comparison; Photon IMRT; Carbon ions; Protons; Gantry