Log on / register
BioMed Central home | Journals A-Z | Feedback | Support | My details
Open AccessHighly AccessShort report

High-dose intensity-modulated radiotherapy for prostate cancer using daily fiducial marker-based position verification: acute and late toxicity in 331 patients

Irene M Lips1 email, Homan Dehnad1 email, Carla H van Gils2 email, Arto E Boeken Kruger3 email, Uulke A van der Heide1 email and Marco van Vulpen1 email

1Department of Radiation Oncology, University Medical Center Utrecht, The Netherlands

2Julius Center for Health Sciences and Primary Care, University Medical Center Utrecht, The Netherlands

3Department of Urology, University Medical Center Utrecht, The Netherlands

author email corresponding author email

Radiation Oncology 2008, 3:15doi:10.1186/1748-717X-3-15

Published: 21 May 2008

Abstract

We evaluated the acute and late toxicity after high-dose intensity-modulated radiotherapy (IMRT) with fiducial marker-based position verification for prostate cancer. Between 2001 and 2004, 331 patients with prostate cancer received 76 Gy in 35 fractions using IMRT combined with fiducial marker-based position verification. The symptoms before treatment (pre-treatment) and weekly during treatment (acute toxicity) were scored using the Common Toxicity Criteria (CTC). The goal was to score late toxicity according to the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer (RTOG/EORTC) scale with a follow-up time of at least three years. Twenty-two percent of the patients experienced pre-treatment grade ≥ 2 genitourinary (GU) complaints and 2% experienced grade 2 gastrointestinal (GI) complaints. Acute grade 2 GU and GI toxicity occurred in 47% and 30%, respectively. Only 3% of the patients developed acute grade 3 GU and no grade ≥ 3 GI toxicity occurred. After a mean follow-up time of 47 months with a minimum of 31 months for all patients, the incidence of late grade 2 GU and GI toxicity was 21% and 9%, respectively. Grade ≥ 3 GU and GI toxicity rates were 4% and 1%, respectively, including one patient with a rectal fistula and one patient with a severe hemorrhagic cystitis (both grade 4). In conclusion, high-dose intensity-modulated radiotherapy with fiducial marker-based position verification is well tolerated. The low grade ≥ 3 toxicity allows further dose escalation if the same dose constraints for the organs at risk will be used.


© 1999-2008 BioMed Central Ltd unless otherwise stated < info@biomedcentral.com >   Terms and conditions