The positioning errors before/after (without/with) online set-up correction in the LR, SI and AP axes in this study (mm) |
|||||||
| LR |
SI |
AP |
|||||
|
|
|||||||
| Before |
After |
Before |
After |
Before |
After |
||
|
|
|||||||
| mean |
0.3 |
0.1 |
0.4 |
0.0 |
-0.2 |
0.0 |
|
| SD |
3.2 |
0.7 |
4.5 |
0.8 |
3.9 |
0.7 |
|
| Range |
-12.0 ~ 13.5 |
-2.6 ~ 1.4 |
-17.2 ~ 16.3 |
-2.5 ~ 1.5 |
-12.9 ~ 10.9 |
-1.9 ~ 1.5 |
|
| Σ |
1.4 |
0.2 |
2.1 |
0.2 |
2.3 |
0.1 |
|
| σ |
3.0 |
0.8 |
4.1 |
0.7 |
3.2 |
0.7 |
|
| Theoretic margin |
7.4 |
1.7 |
10.2 |
1.6 |
8.8 |
1.7 |
|
| Translational shift |
4.4 |
7.2 |
5.8 |
||||
|
Before: before online set-up correction; After: after online set-up correction; Theoretic margin: calculated by 2.27 × SD based on a pre-selected confidence level of 98%; Translational shift: translational shift of the treatment isocenter in simulated IMRT plan to cover the theoretic margin without online set-up correction in three axes, and calculated as "theoretic margin before online set-up correction-3" mm. | |||||||